Confined spaces are among the most hazardous work environments in industrial operations. Poor ventilation, toxic gases, engulfment risks, extreme temperatures, and limited access make confined space incidents fatal within seconds. To control these risks, organizations must perform a Confined Space HIRA (Hazard Identification & Risk Assessment) before any worker enters.

A well-structured HIRA identifies hazards, evaluates their severity and likelihood, assigns risk ratings, and establishes strong control measures to protect entrants, attendants, and rescue teams. This guide explains a complete confined space HIRA tailored for industrial operations.


What Is Confined Space HIRA?

Confined Space HIRA is a systematic process that focuses on:

  • Recognizing hazards
  • Assessing risks
  • Implementing control measures
  • Documenting safe entry requirements
  • Ensuring compliance with legal and safety standards

It is mandatory under confined space regulations worldwide.


Why HIRA Is Critical for Confined Space Work

Industrial confined spaces can quickly become life-threatening due to:

  • Toxic gas accumulation
  • Oxygen deficiency
  • Flammable vapors
  • Heat stress
  • Limited escape routes
  • Mechanical or chemical hazards

HIRA helps prevent fatal accidents by ensuring hazards are known, understood, controlled, and monitored.


Hazard Categories in Confined Space Industrial Operations

Confined space hazards fall into major categories:


Atmospheric Hazards

Oxygen Deficiency

Occurs due to:

  • Rusting
  • Chemical reactions
  • Gas displacement

Less than 19.5% oxygen can cause rapid unconsciousness.

Toxic Gases

Common industrial toxins:

  • Hydrogen sulfide (Hâ‚‚S)
  • Carbon monoxide (CO)
  • Ammonia
  • Methane
  • Nitrogen dioxide

These gases can be lethal without warning.

Flammable or Explosive Atmosphere

When vapors reach 10% LEL, the environment becomes explosive.


Engulfment Hazards

Entrants can be engulfed by:

  • Sludge
  • Sand
  • Grain
  • Chemicals
  • Water

Engulfment is one of the most fatal confined space hazards.


Physical Hazards

Include:

  • Falling objects
  • Hot or sharp surfaces
  • Noise
  • Poor visibility
  • Slippery floors
  • Structural instability

Mechanical & Energy Hazards

Hazards include:

  • Rotating machinery
  • Agitators
  • Mixers
  • Pumps
  • Conveyors

LOTO (Lockout/Tagout) is mandatory before entry.


Thermal Hazards

High heat can cause:

  • Heat stress
  • Dehydration
  • Fatigue
  • Collapse

Low temperatures increase risk of cold stress.


Biological Hazards

Common in sewers, tanks, and wastewater pits:

  • Bacteria
  • Fungi
  • Contaminated water
  • Sewage gases

Psychological & Ergonomic Hazards

Entrants may face:

  • Claustrophobia
  • Stress
  • Panic
  • Fatigue
  • Restricted movement

These increase the likelihood of mistakes.


Confined Space HIRA Table for Industrial Operations

Below is a structured HIRA table you can use for industrial confined space work.


Confined Space HIRA Table

HazardRisk DescriptionPossible ConsequencesRisk Level (Before Control)Control MeasuresResidual Risk
Oxygen deficiencyOâ‚‚ <19.5%Unconsciousness, deathHighPre-entry testing, ventilation, continuous gas monitoring, SCBALow
Toxic gases (Hâ‚‚S, CO)Inhalation of gasesRespiratory failure, deathHighVentilation, gas detectors, alarms, SCBALow
Flammable gasesVapors near ignition sourceExplosion, burnsHighIntrinsically safe tools, EX-rated equipment, gas monitoringLow
EngulfmentSludge, water, grain collapseSuffocation, entrapmentHighBarriers, dewatering, entry harness, rescue planMedium
Mechanical hazardsMoving parts, agitatorsAmputation, crush injuryHighLOTO, isolation, mechanical guardsLow
Electrical hazardsExposed wiring, equipmentShock, burnsMediumLockout, insulated tools, GFCILow
Heat stressHigh temperatureCollapse, dehydrationMediumVentilation, cooling breaks, hydrationLow
Slip/Trip hazardsWet/slippery floorsInjury, sprainsMediumHousekeeping, anti-slip mats, lightingLow
Poor communicationNoise or obstructionsDelayed response, panicMediumRadios, attendants, hand signalsLow
Restricted accessOnly one entry/exitRescue difficultyHighTripod/winch system, rescue team standbyMedium
Chemical exposureLiquid or vapor releaseBurns, poisoningHighPPE, chemical-resistant gloves & suitsLow
Biological contaminantsSewage, microbesInfection, illnessMediumPPE, hygiene protocolsLow

This table can be expanded depending on the operation.


Hierarchy of Controls for Confined Space Hazards

HIRA must follow recognized control hierarchy:

Elimination

Remove the need to enter — use remote tools if possible.

Substitution

Use less hazardous chemicals.

Engineering Controls

  • Ventilation
  • Isolation
  • Barriers
  • Gas monitoring systems

Administrative Controls

  • Permit-to-work
  • Training
  • SOPs
  • Supervision

PPE

Last line of defense — harness, respirators, gloves, etc.


Step-by-Step Confined Space HIRA Process


Step 1: Identify the Confined Space

Analyze:

  • Purpose
  • Size
  • Access points
  • Potential hazards
  • Isolation requirements

Step 2: Identify Hazards Present

A hazard checklist should include:

  • Atmospheric hazards
  • Energy sources
  • Engulfment risks
  • Chemical exposure
  • Biological agents
  • Electrical hazards
  • Noise
  • Temperature

Step 3: Evaluate Risk Severity and Likelihood

Assess:

  • Potential impact
  • Exposure duration
  • Frequency of work
  • Environmental conditions

Assign risk rating (High/Medium/Low).


Step 4: Establish Control Measures

Controls include:

  • Ventilation
  • Gas testing
  • PPE
  • LOTO
  • Attendant monitoring
  • Rescue equipment ready

Step 5: Implement Safe Work Procedures

This includes:

  • Permit-to-work system
  • Pre-entry checklist
  • Toolbox talk
  • Authorized personnel only

Step 6: Monitor the Work Continuously

Monitor:

  • Gas levels
  • Worker condition
  • Communication
  • Ventilation performance
  • Environmental changes

Step 7: Document the HIRA

Documentation ensures:

  • Traceability
  • Accountability
  • Compliance

Step 8: Review and Update HIRA

HIRA must be updated when:

  • New hazards identified
  • Change in work conditions
  • New materials introduced
  • Near miss or incident occurs

Control Measures for Common HIRA Findings


Atmospheric Controls

Mechanical Ventilation

Use blowers or ducts.

Pre-entry and continuous testing

Using calibrated multi-gas detectors.

Respiratory protection

APR, SAR, SCBA depending on hazard.


Physical Hazard Controls

Lighting

Intrinsically safe lights.

Fall prevention

Harness and tripod system.

Noise reduction

Hearing protection where needed.


Engulfment Controls

Barriers and dewatering

Remove liquid or solids before entry.

Harness with retrieval line

Prevents full engulfment.


Administrative Controls

Training

Entrants, attendants, and supervisors.

Permit-to-work

Mandatory.

Role clarity

Entrants, attendants, rescue team.


PPE Controls

Mandatory PPE includes:

  • Helmet
  • Safety boots
  • Gloves
  • Protective suit
  • Goggles
  • Harness
  • Lifeline
  • Gas detector

Confined Space HIRA Example for Common Industrial Spaces

Manholes

Major hazards:

  • Hâ‚‚S
  • Methane
  • Oxygen deficiency
  • Drowning
  • Slips

Tanks

Hazards:

  • Chemical vapors
  • Residue
  • Heat
  • Engulfment

Boilers

Hazards:

  • Heat stress
  • Limited mobility
  • Pressure hazards

Each confined space requires its own HIRA.


Conclusion

A Confined Space HIRA for industrial operations is not just a document — it is the foundation of safe confined space work. Identifying hazards, analyzing risks, and implementing effective control measures protect workers from invisible and deadly dangers. With proper planning, monitoring, and rescue readiness, confined space entries can be carried out safely and efficiently.

Confined space hazards are unforgiving — but a strong HIRA saves lives.

For checklist and templates visit The HSE Tools.

Emergency Rescue Procedures for Confined Space Entry

Duties of Confined Space Attendants and Entrants

Ventilation Requirements for Confined Spaces

Confined Space Atmospheric Testing – Gas Detection Explained

Confined Space Entry Permit System Explained


FAQs

1. Is HIRA mandatory for confined space entry?

Yes, it is legally required in most safety regulations.

2. How often should HIRA be updated?

Whenever conditions change or after any incident or near miss.

3. Who performs the confined space HIRA?

Safety officers, supervisors, and competent persons together.

4. Are gas detectors part of the HIRA process?

Yes, atmospheric monitoring is a key hazard control.

5. Is the rescue plan part of the HIRA?

Yes — rescue requirements must be documented within HIRA.

HSE Professional, Blogger, Trainer, and YouTuber with 12+ years of industry experience across India and the Gulf. Founder of HSE STUDY GUIDE and The HSE Coach, sharing safety tips, training content, and certification support. 📘 Facebook | 📸 Instagram | 🎥 YouTube (HSE STUDY GUIDE) | 🎥 YouTube (The HSE Coach)

Leave a Comment